Core quantities · Beginner · 300 min
C-rate
What "1C" and "3C" actually mean, how to compute charge and discharge times, and why the ideal answer is always optimistic.
By the end of this lesson you can
- Calculate C-rate from current and rated capacity
- Calculate the current that corresponds to a given C-rate
- Estimate the idealised charge or discharge time and explain why real times differ
- Explain why identical cells in parallel share the same C-rate as the pack
Before this: Capacity and energy (Ah vs Wh)
The C-rate expresses current relative to a battery's capacity: 1C is the current that would discharge the rated capacity in one hour. It allows cells of very different sizes to be compared under the same relative stress. The same 10 A is gentle for a 50 Ah cell and severe for a 2 Ah cell, and datasheet limits, test procedures and ageing data are all stated in C-rates for this reason.
Study plan · two days
- Day 1 (about 2.5 h): The C-rate. The idea, the definition, a worked example and a calculator. Knowledge check.
- Day 2 (about 2.5 h): C-rate in packs and datasheets. Converting between pack and cell C-rates, and reading datasheet current limits. Homework and further reading.
Day 1 · about 2.5 h
The C-rate
The idea in one sentence
C-rate measures current relative to the battery's size. A current of 1C would, ideally, empty (or fill) the battery's rated capacity in one hour. 2C is twice that current and would take half an hour. C/2 (or 0.5C) is half the current and would take two hours.
Because it is relative, 10 A is a gentle 0.2C for a 50 Ah cell but a punishing 5C for a 2 Ah cell. C-rate tells you how hard the battery is working, which raw amperes cannot.
The definition
- — charge or discharge current magnitude, in amperes (A)
- — the rated (nominal) capacity from the datasheet, in ampere-hours (Ah)
With A divided by Ah the unit is 1/h, which is written simply as "C". Rearranging gives the two forms you will use most:
Use the rated capacity, not the charge remaining in the battery right now. C-rate describes current, not state of charge.
Maths· Why 1/C-rate is only an ideal time
The ideal time assumes the battery delivers exactly at any current. Integrating a constant current gives the charge moved: , so .
Real cells deliver somewhat less usable capacity at high discharge currents. Internal resistance makes the terminal voltage hit the cut-off voltage earlier (). Charging is limited by the constant-voltage phase, where current tapers. Both effects make the real time longer than for a full charge. That is why "a 2C charger fills the battery in 30 minutes" is never quite true.
Worked example
Worked example
A 5 Ah cell at 15 A
A cylindrical cell is rated at . It is discharged at a constant .
- C-rate
- Ideal discharge time
- Current for a gentle C/5 discharge: , with an ideal time of
Sanity check: a higher C-rate means more current, which means a shorter time. 3C at 20 minutes is consistent.
Try it
C-rate
Illustrative modelAssumptions
- C-rate = I / Q_rated, using the datasheet rated capacity.
- Ideal time = Q / I. It ignores the CV taper when charging, the reduced usable capacity at high discharge current, temperature and ageing, so real times are longer for a full charge.
Where engineers use C-rate
- Datasheets state maximum continuous and peak C-rates for charge and discharge, often at a specified temperature. They are not interchangeable: charge limits are usually lower than discharge limits.
- Test procedures are written in C-rates (for example, "discharge at C/3 to the cut-off voltage") so that one procedure works for cells of any size.
- Pack design: in an
s × ppack of identical cells, the pack current splits acrosspparallel cells and the pack capacity isptimes the cell capacity. The pack C-rate equals the cell C-rate. This is a useful check when you size packs. - Fast charging is often discussed as a C-rate (or a power-based "P-rate" in kW per kWh). Charging an energy-rated pack at a power equal to twice its kWh capacity is roughly a 2C power rate. The current-based C-rate differs slightly because the voltage varies during the charge.
Simulator
Common mistakes
- Using the remaining charge instead of the rated capacity. 10 A from a 50 Ah cell is 0.2C whether the cell is full or half-empty.
- Reading "C" as coulombs. In C-rate, "C" stands for capacity. A coulomb (also written C) is a unit of charge; they are different things.
- Trusting 1/C-rate as the real charge time. It ignores the CV taper and rate-dependent capacity.
- Mixing cell and pack numbers. Use cell current with cell capacity, or pack current with pack capacity, never one of each.
Check your understanding
Day 2 · about 2.5 h
C-rate in packs and datasheets
C-rate in a pack
Worked example
A 4p pack at 40 A
A pack of 4 cells in parallel, each 5 Ah, so 20 Ah in total, delivers 40 A.
- Pack C-rate: C
- Each cell carries 10 A (if sharing is equal), which is C
The C-rate is the same at pack and cell level only when parallel cells share current equally (C02-L05).
Reading a datasheet
Typical datasheet current statements
Standard
- Rate at which capacity is rated (e.g. 0.2C)
- Basis of the Ah figure
Maximum continuous
- Highest sustained current
- Often temperature-dependent
Peak (pulse)
- Short bursts, e.g. 10 s
- Limited by heating and voltage
Homework
Homework · answers not provided
- A 2p configuration of 50 Ah cells delivers 150 A. Compute the pack and cell C-rates.
- Find a cell datasheet and list its standard, maximum continuous and peak currents in amperes and as C-rates.
- Explain why capacity measured at 1C is usually lower than at 0.2C.
- Use the C-rate calculator in the lesson to convert 0.5C, 1C and 3C into currents for a 280 Ah storage cell.
Further reading
Further reading
- G. L. Plett, Battery Management Systems, Volume I, Artech House, 2015.
- IEC 61960-3, secondary lithium cells and batteries for portable applications (test conditions).
Key takeaways
- C-rate = current ÷ rated capacity; 1C ideally moves the rated capacity in one hour.
- and hours.
- Real charge and discharge times are longer than ideal, especially at high C-rates.
- Identical cells in parallel experience the same C-rate as their pack.
- C-rate = current ÷ capacity: 40 A from a 20 Ah pack is 2C.
- Pack and cell C-rates match only when parallel cells share current equally.
Sources for this lesson are listed on the References page.