Skip to content
Battery Engineering Academy

Battery calculators.

Quick engineering calculators. Every result is checked against our Python reference implementation, and each tool lists its assumptions. These are teaching models, not predictions for a specific cell.

Battery energy

Illustrative model
V
Ah
Energy
18.5 Wh
Energy
0.0185 kWh
Energy
66.6 kJ
Charge
18,000 C

Assumptions
  • E = V_nominal × Q. This is a nominal value, not the energy delivered under every condition.
  • Real delivered energy falls at high current, low temperature and with ageing.
  • 1 Wh = 3600 J.

Series / parallel pack

Illustrative model
V
Ah
s
p
Pack voltage
46.8 V
Pack capacity
20 Ah
Pack energy
0.936 kWh
Cells
52

Illustrative current sharing among the 4 parallel cells of one series group

A
%
  • Cell 19.302 A
  • Cell 210.23 A
  • Cell 310.23 A
  • Cell 410.23 A

Assumptions
  • All cells identical for the voltage, capacity and energy results.
  • Pack voltage = S × cell voltage; pack capacity = P × cell capacity.
  • Current sharing: one parallel cell's branch resistance is raised by the mismatch %, the others are 20 mΩ. Equal open-circuit voltages; instantaneous DC split I_k ∝ 1/R_k. Real cells rebalance over time as their SOCs diverge.

C-rate

Illustrative model
Ah
A
C-rate
3 C
Ideal time
20 min
Ideal time
0.3333 h

C
Required current
2.5 A
Assumptions
  • C-rate = I / Q_rated, using the datasheet rated capacity.
  • Ideal time = Q / I. It ignores the CV taper when charging, the reduced usable capacity at high discharge current, temperature and ageing, so real times are longer for a full charge.

RC circuit step response

Illustrative model
Ω
µF
V
V
Time constant τ
1 s
v at 1τ
3.161 V
Initial current
5 mA
0τ1τ2τ3τ4τ5τ5 V0 Vtime →

Assumptions
  • Ideal source, resistor and capacitor: no leakage, constant C.
  • v(t) = Vs + (v0 − Vs)·e^(−t/τ), τ = R·C. Set Vs = 0 to see a discharge.
  • This is the same first-order behaviour as the RC branch of a battery equivalent-circuit model (C12), but a real cell is not a capacitor.