The electrical basics · Beginner · 300 min
Power versus energy: W, Wh, kWh
Power is how fast energy flows; energy is how much there is. The difference that decides whether a battery can run your load, and for how long.
By the end of this lesson you can
- Calculate electrical power from voltage and current, and convert between W and kW
- Calculate energy from power and time, and convert between Wh, kWh and joules
- Estimate runtime, EV range and charging cost from energy and power figures
- Explain why a battery must meet both an energy requirement and a power requirement
Before this: Voltage and electrical potential
Power and energy are often confused, but they answer different questions. Power, in watts, is the rate at which energy flows; energy, in watt-hours, is the amount transferred. A battery's energy rating says how long it can run a load; its power rating says how large a load it can run. Electricity bills charge for energy, while cables, inverters and fuses are sized for power.
Study plan · two days
- Day 1 (about 2.5 h): Rate and amount. Power and energy, the equations, worked examples and a calculator. Practice drills and the knowledge check.
- Day 2 (about 2.5 h): Power and energy in practice. Running time and electricity cost, and sizing equipment for peak power. Homework and further reading.
Day 1 · about 2.5 h
Rate and amount
Rate and amount
Think of filling a bucket from a tap.
- How far the tap is open is the rate: litres per minute. For electricity, the rate is power, measured in watts (W).
- How much water ends up in the bucket is the amount: litres. For electricity, the amount is energy, measured in watt-hours (Wh) or joules (J).
A wide-open tap for a short time and a trickle for a long time can fill the same bucket. In the same way, 1,000 W for one hour and 100 W for ten hours both use 1,000 Wh = 1 kWh.
A battery has both a size (how much energy it holds) and a pipe width (how much power it can deliver). They are separate limits.
The equations
Electrical power is voltage times current:
- : power, in watts (W);
- : voltage, in volts (V)
- : current, in amperes (A)
Energy is power multiplied by time, when the power is constant:
- : energy, in watt-hours (Wh) when is in hours, or joules (J) when is in seconds
- : time
Conversions: ; . On an Indian electricity bill, one "unit" is one kWh.
Rearranged, the two most useful battery questions are:
Maths· When power is not constant
Real loads vary: a fridge cycles on and off and a car accelerates and brakes. Energy is then the area under the power–time curve:
The average power over the interval is . This is why a fridge rated 150 W, running only part of the time, can use far less than per day. To estimate energy, you need the average power, not the nameplate power.
Solved examples
Worked example
Example 2.1: phone fast charging
A USB-C charger negotiates 9 V at 2 A.
- Power:
- A 19.25 Wh phone battery (from C06-L01), filled at a constant 18 W with no losses, would take , about 64 minutes.
Reality check: real charging takes longer, because some energy is lost as heat and the charger slows down near full (C01-L06, C06-L09). Treat as the best case.
Worked example
Example 2.2: home inverter backup
A home inverter battery stores 1.8 kWh nominal (for example 12 V × 150 Ah). During a power cut it supplies a fan, lights and a Wi-Fi router drawing a steady 300 W in total.
- Ideal runtime:
- Suppose the system uses only 80 % of the nominal energy (an assumed figure, to protect the battery) and the inverter is 85 % efficient (also assumed). Then the runtime is
Lesson: the nameplate kWh is an upper bound. Real runtime depends on how much of the battery is used and on conversion losses.
Worked example
Example 2.3: enough energy, not enough power
A home battery stores 5 kWh, but its inverter can deliver at most 3 kW. You want to run a 2 kW air conditioner and a 3 kW water heater together.
- Total power:
- That is more than the 3 kW limit, so it cannot run both at once, however much energy is stored.
- The air conditioner alone (2 kW) is within the limit. It could run for up to (ideal).
Energy decides how long. Power decides whether it can run at all. This is why battery systems are specified with both a kWh and a kW rating.
Worked example
Example 2.4: EV range and charging cost
A small EV has 30 kWh of usable energy and uses on average 150 Wh per km.
- Range:
- At an average 60 km/h, the average power drawn is
- Recharging 30 kWh at an assumed ₹8 per unit (tariffs vary by state, slab and time of day) costs , before charging losses
Sanity check: 200 km for ₹240 is about ₹1.2 per km, an order of magnitude that matches the usual "EVs are cheap per km" claim. The result depends entirely on the assumed tariff and consumption.
Try it
Battery energy
Illustrative modelAssumptions
- E = V_nominal × Q. This is a nominal value, not the energy delivered under every condition.
- Real delivered energy falls at high current, low temperature and with ageing.
- 1 Wh = 3600 J.
Simulator
Where engineers use this
- Battery system datasheets give both energy (kWh) and continuous and peak power (kW). The ratio of power to energy (kW per kWh, also written as a C-rate; C06-L02) separates "energy" designs, such as a home battery that runs for hours, from "power" designs, such as a hybrid car's battery that delivers short bursts.
- EVs: range depends on energy and consumption (Wh/km); acceleration and fast-charging depend on power.
- Grid storage is described as, for example, "100 MW / 400 MWh": 100 MW of power for 4 hours.
- Electricity bills charge for energy (kWh). Some commercial tariffs also charge for peak power (kW), because the grid must be built for the peak.
Common mistakes
- Writing "kW" when you mean "kWh" (or the reverse). A "5 kW battery" says nothing about how long it lasts.
- "kW per hour". Power is already a rate. kWh is kW multiplied by hours, not divided.
- Using nameplate power for energy. A 150 W fridge does not use 3.6 kWh a day, because it does not run all the time. Use average power.
- Ignoring the power limit. A big battery behind a small inverter cannot run a big load.
- Treating E/P as the real runtime. Losses, the usable window and ageing all shorten it.
Practice
Numbers change each time you press New values. Answers within about 1 % are accepted.
- D1
A charger supplies 12 V at 2 A. What power is that, in W?
- D2
A load draws a steady 300 W for 2 hours. How much energy does it use, in Wh?
- D3
A battery stores 1,800 Wh. Ideally, how many hours can it supply a steady 250 W load?
- D4
An EV has 40 kWh usable and uses 150 Wh/km. What is its estimated range, in km?
- D5
Recharging uses 30 kWh at an assumed tariff of ₹6.5 per unit (kWh). What does it cost, in ₹, ignoring charging losses?
Check your understanding
Day 2 · about 2.5 h
Power and energy in practice
From energy to cost
Worked example
Example 2.5: running a 3 kW load
A 3 kW air conditioner runs for 4 hours on a tariff of ₹8 per kWh.
- Energy: kWh
- Cost:
Sizing for power
Equipment is sized for the largest power it must carry, not the average. A home battery that supplies an average of 500 W may need to deliver 3 kW for a few seconds when a motor starts. The inverter, cables and protection must handle the peak; the battery's energy must cover the average over the backup period.
Power and energy ratings
Power (W, kW)
- Rate of energy flow
- Sizes inverters, cables, fuses
- Limits acceleration, start-up loads
Energy (Wh, kWh)
- Amount stored or used
- Sets running time and range
- What electricity bills charge for
Homework
Homework · answers not provided
- A 1.2 kWh power station runs a 60 W fan and a 15 W lamp. How long does it last? What is the cost of recharging it at ₹8 per kWh?
- A home backup system must supply 400 W average for 6 hours and start a 2 kW pump. Specify its energy and power ratings with a 20 % margin.
- Explain why a battery's runtime at very high power is often less than E/P.
- List three devices in your home and estimate their daily energy use and monthly cost.
Further reading
Further reading
- OpenStax, University Physics Volume 2, chapters on electric current and power.
- G. L. Plett, Battery Management Systems, Volume I, Artech House, 2015.
Key takeaways
- Power (W, kW) is the rate; energy (Wh, kWh, J) is the amount. and .
- , and one electricity "unit" is one kWh.
- Runtime is in the ideal case; real runtime is shorter.
- A battery must meet two separate requirements: enough energy (how long) and enough power (whether it can run the load at all).
- Energy (kWh) sets running time and cost: 3 kW for 4 h is 12 kWh, ₹96 at ₹8/kWh.
- Size inverters and cables for peak power; size the battery for energy over the period.
- Next: series and parallel connections, which set a pack's voltage, capacity, energy and power.
Sources for this lesson are listed on the References page.