Circuits for batteries · Beginner · 300 min
Series and parallel connections
How connecting cells in series raises voltage, how connecting them in parallel raises capacity, what "13s4p" means, and what happens when the cells are not identical.
By the end of this lesson you can
- Calculate pack voltage, capacity and energy for an s×p configuration of identical cells
- Calculate pack resistance and the current carried by each cell
- Choose a series count for a target voltage and check the full-charge voltage
- Explain how mismatched cells behave in series and in parallel
Before this: Power versus energy: W, Wh, kWh
Battery packs are built by connecting cells in series, which adds their voltages, and in parallel, which adds their capacities. The arrangement, written for example as 13s4p, determines the pack's voltage, capacity, energy and internal resistance. It also determines how the pack behaves when its cells are not perfectly matched, which they never are.
Study plan · two days
- Day 1 (about 2.5 h): Series and parallel connections. The pack equations, worked examples, a calculator, and mismatched cells. Practice drills and the knowledge check.
- Day 2 (about 2.5 h): Designing a pack. A complete 48 V pack calculation, and current sharing between parallel cells. Homework and further reading.
Day 1 · about 2.5 h
Series and parallel connections
Two ways to connect cells
- Series connects cells end to end, positive to negative, like steps on a staircase. Each cell lifts the voltage by its own amount, so voltages add. The same current flows through every cell.
- Parallel connects cells side by side, positives together and negatives together, like extra lanes on a road. The voltage stays the same, but the cells share the current, so capacities add.
Packs combine both. "13s4p" means 4 cells in parallel form a group, and 13 such groups are connected in series: cells in total.
The pack equations
For groups in series, each made of identical cells in parallel:
- : cell voltage (nominal, maximum or minimum: use the same one throughout), in V
- : cell capacity, in Ah
- : cell energy, in Wh
Resistance and current. Resistances add in series and divide in parallel, so with identical cells of resistance (ignoring interconnects):
Each cell in a group carries of the pack current, so every cell runs at the same C-rate as the pack (C06-L02).
The full-charge and empty voltages matter as much as the nominal one. A pack swings between and , and the charger, motor controller and insulation must handle the whole range.
Series / parallel pack
Illustrative modelIllustrative current sharing among the 4 parallel cells of one series group
- Cell 19.302 A
- Cell 210.23 A
- Cell 310.23 A
- Cell 410.23 A
Assumptions
- All cells identical for the voltage, capacity and energy results.
- Pack voltage = S × cell voltage; pack capacity = P × cell capacity.
- Current sharing: one parallel cell's branch resistance is raised by the mismatch %, the others are 20 mΩ. Equal open-circuit voltages; instantaneous DC split I_k ∝ 1/R_k. Real cells rebalance over time as their SOCs diverge.
Solved examples
Worked example
Example 5.1: an e-scooter pack
A 13s4p pack uses cells rated 3.6 V, 5.0 Ah and .
- Voltage: (a "48 V class" pack)
- Capacity:
- Energy:
- Resistance:
- At a 40 A pack current, each cell carries (2C). The pack voltage sags by , and the cells turn into heat.
Sanity check: 130 W of heat out of about 1.7 kW delivered is roughly 7–8 %, a significant loss that the pack's thermal design must handle (C02-L06).
Worked example
Example 5.2: choosing the series count for an EV
A car maker wants a "400 V class" pack from NMC cells with a nominal 3.65 V and a maximum of 4.2 V.
- Series count: . Choose a whole number near it, for example 110s
- Nominal voltage:
- Full-charge voltage:
The charger, inverter and insulation must be rated for at least 462 V, not 400 V. "400 V" names the class, not the maximum.
Worked example
Example 5.3: two parallel branches that do not match
Two cells are connected in parallel. One has 20 mΩ of resistance, including its connection, and the other 25 mΩ. Both start at the same open-circuit voltage, and the pair supplies 30 A.
Current splits in inverse proportion to resistance:
The lower-resistance cell works about 25 % harder, so it warms up more and can age faster. Over time its SOC falls faster, its OCV drops, and the split partly rebalances. This is why pack designers match cell resistance and make interconnects equal (C09).
When cells are not identical
- In series, every cell carries the same current, so the weakest cell sets the limit. The string is empty when its lowest cell reaches the minimum voltage, and full when its highest cell reaches the maximum. Small differences in capacity and SOC waste usable energy, which is why packs need balancing (C10).
- In parallel, cells are forced to the same terminal voltage and they share current by resistance (Example 5.3). Parallel groups partly self-balance, but a cell with a fault, such as an internal short, can draw current from its neighbours. That is why many packs fuse each cell or each group.
- Never connect cells in parallel at very different voltages. The equalising current is limited only by their small resistances and can be very large.
Maths· Why parallel current splits by conductance
Treat each branch as an ideal voltage source in series with a resistance . All branches share the terminal voltage , so . Summing gives , so:
For two branches, this reduces to . Equal OCVs are an assumption that holds only at the instant the load is applied; as the branches drift apart in SOC, the OCVs differ and the split changes.
Simulator
Common mistakes
- Swapping s and p. 13s4p and 4s13p use the same 52 cells but give 46.8 V/20 Ah versus 14.4 V/65 Ah.
- Designing for the nominal voltage only. Size chargers and insulation for and controllers for .
- Forgetting that cell current is . A cell's current limit sets the pack's current limit only after you multiply by .
- Assuming parallel cells share current equally. That is true only if their resistances and OCVs match.
- Paralleling cells at different SOCs. It causes a large, uncontrolled equalising current.
Practice
Numbers change each time you press New values. Answers within about 1 % are accepted.
- D1
A pack has 14 cell groups in series. Each cell has a nominal 3.6 V. What is the pack's nominal voltage, in V?
- D2
Each parallel group has 4 cells of 3 Ah. What is the pack capacity, in Ah?
- D3
A 13s3p pack uses identical cells of 20 mΩ. Ignoring interconnects, what is the pack resistance, in mΩ?
- D4
You choose 20 groups in series of NMC cells with a maximum voltage of 4.2 V. What is the full-charge pack voltage the charger must handle, in V?
- D5
Two parallel branches with equal OCV have resistances R1 = 20 mΩ and R2 = 25 mΩ. Together they supply 20 A. What current flows in branch 1, in A?
Check your understanding
Day 2 · about 2.5 h
Designing a pack
A 48 V pack
Worked example
Example 5.4: 13s4p of 3.6 V, 5 Ah cells
Each cell: 3.6 V nominal, 5 Ah, 25 mΩ.
- Voltage: V
- Capacity: Ah
- Energy: Wh
- Resistance: mΩ (cells only; interconnects add more)
- Voltage drop at 40 A: V
Unequal sharing
Worked example
Example 5.5: one weaker connection
Two parallel branches share 40 A; one has 25 mΩ, the other 30 mΩ.
- Current in the 25 mΩ branch: A; the other carries 18.2 A
The lower-resistance branch works harder, heats more, and may age faster. Pack design keeps interconnect resistances equal and matches cells in each parallel group.
Series and parallel
Series (s)
- Adds voltage
- Same current through every cell
- Needs cell balancing
Parallel (p)
- Adds capacity
- Cells share current by resistance
- Self-balances in voltage
Homework
Homework · answers not provided
- Design a pack of about 72 V and at least 2 kWh from 3.6 V, 5 Ah cells. State the configuration, energy and resistance.
- In Example 5.5, how large must the resistance difference be for one branch to carry 60 % of the current?
- Explain why a series string needs balancing but a parallel group does not.
- Use the pack calculator in the lesson to check your answer to question 1.
Further reading
Further reading
- OpenStax, University Physics Volume 2, chapters on circuits.
- G. L. Plett, Battery Management Systems, Volume II, Artech House, 2016. Pack-level estimation and balancing.
Key takeaways
- Series adds voltage; parallel adds capacity. , , .
- , and each cell carries .
- Check the full-charge and empty voltages, not only the nominal one.
- In series, the weakest cell limits the string. In parallel, current splits by conductance.
- 13s4p of 3.6 V, 5 Ah, 25 mΩ cells gives 46.8 V, 20 Ah, 936 Wh and 81 mΩ.
- Parallel branches share current inversely to resistance; match interconnects and cells.
- Next: efficiency and losses, where the heat in Example 5.1 comes from and why it matters.