Batteries for the grid and beyond · Beginner · 300 min
Grid storage: why cost and cycle life beat energy density
Grid batteries store solar power for the evening and steady the grid. They do not move, so weight hardly matters, but they cycle every day for years. That changes which battery wins.
By the end of this lesson you can
- Interpret a grid battery rating in MW and MWh and calculate its duration
- Calculate round-trip efficiency from energy in and energy out
- Calculate a simplified cost per kWh delivered over life, and explain why cycle life can outweigh up-front cost
- Explain why energy density matters much less for stationary storage than for vehicles
Before this: Power versus energy: W, Wh, kWh · Scooters, cars, buses and trucks: one chemistry does not fit all
Grid batteries are rated differently from vehicle batteries. A power rating in megawatts states how fast they can deliver; an energy rating in megawatt-hours states for how long. Their value depends on round-trip efficiency, on how many cycles they can deliver over their life, and on what each delivered kilowatt-hour costs. These ratings, not energy per kilogram, decide which battery technology wins on the grid.
Study plan · two days
- Day 1 (about 2.5 h): Grid batteries and their ratings. What grid batteries do, power and energy ratings, duration and efficiency, and why cost per delivered kWh matters. Practice drills and the knowledge check.
- Day 2 (about 2.5 h): Comparing storage offers. Lifetime cost per delivered kWh for two offers, and what the simple figure leaves out. Homework and further reading.
Day 1 · about 2.5 h
Grid batteries and their ratings
What grid batteries do
- Time-shifting: store cheap or surplus energy (for example midday solar) and release it when demand is high.
- Keeping the grid steady: the grid's frequency must stay very close to its set value (50 Hz in India). Batteries can respond in a fraction of a second to small imbalances.
- Backup and peak support: cover short peaks so that the grid does not need extra power plants or lines that would sit idle most of the year.
Each job needs a different balance of power (how fast) and energy (how long), the distinction from C02-L04.
Reading a grid battery's rating
Grid systems are rated with two numbers, for example 100 MW / 400 MWh:
- 100 MW is the maximum power it can deliver (or absorb).
- 400 MWh is the energy it can deliver.
- The duration is their ratio: hours at full power.
Round-trip efficiency (RTE) is how much of the energy you put in comes back out:
The losses come from cell resistance, power electronics, and cooling and other auxiliaries.
A simplified cost per kWh delivered spreads the up-front battery cost over all the energy it will ever deliver:
- capex per kWh: installed battery cost per kWh of capacity, in ₹/kWh
- : cycles to end of life
- DoD and RTE as fractions
This leaves out financing, operation and maintenance, gradual fade and replacement, so it is a teaching simplification. Real project economics use a levelised cost of storage (LCOS), covered in C09.
Solved examples
All costs below are hypothetical round numbers for comparison only. They are not market prices.
Worked example
Example 7.1: duration
A system is rated 100 MW / 400 MWh. At full power it runs for . At half power (50 MW) it would run for about 8 h, ignoring efficiency changes.
Worked example
Example 7.2: round-trip efficiency
Over a day, 100 MWh is taken from the grid to charge the system and 88 MWh is returned in the evening.
The missing 12 MWh became heat in the cells, the inverters and the cooling system.
Worked example
Example 7.3: cheaper to buy, or cheaper to own?
Two hypothetical battery options, both cycled once a day at 90 % DoD with 90 % RTE:
| Option A | Option B | |
|---|---|---|
| Installed cost | ₹10,000 per kWh | ₹12,000 per kWh |
| Cycle life | 3,000 cycles | 6,000 cycles |
| Years at 1 cycle/day | about 8.2 | about 16.4 |
| Cost per kWh delivered |
Option B costs 20 % more up front but delivers each kWh about 40 % cheaper over its life. For a battery that cycles every day, cycle life is worth more than a low purchase price.
Worked example
Example 7.4: does weight matter?
How heavy would 400 MWh of batteries be at an illustrative 150 Wh/kg (pack level), compared with 100 Wh/kg?
- tonnes
- tonnes
For a car, that difference would be decisive. For a battery sitting on a concrete pad, the extra mass costs a little more foundation and a few more containers. That is minor compared with the cost per kWh delivered.
Simulator
Why this changes which battery wins
- Cost and cycle life dominate (Example 7.3), followed closely by safety: thousands of cells in one place must not be able to spread a fire from cell to cell (C11).
- Energy density matters much less (Example 7.4), although footprint still matters where land is expensive.
- These priorities favour long-life, thermally stable chemistries. LFP is widely used in stationary storage today, and sodium-ion is a candidate for some applications (C01-L12). As in C01-L04, this lesson gives no market shares; later lessons that do will state the source, date and region.
- Duration is a design choice: short-duration systems (around 1 hour) suit grid-frequency services, and longer ones (4 hours or more) suit solar time-shifting.
Common mistakes
- Quoting only MW or only MWh. A grid battery needs both: power and duration.
- Comparing batteries by purchase price alone. For daily cycling, cost per kWh delivered over life is the fairer comparison.
- Ignoring round-trip losses. 10–15 % lost every day adds up over thousands of cycles.
- Applying vehicle priorities to stationary storage. Light and compact matters far less than long-lived and safe.
Practice
Numbers change each time you press New values. Answers within about 1 % are accepted.
- D1
A grid battery is rated 50 MW / 200 MWh. How many hours can it deliver its full power?
- D2
A storage system takes 200 MWh from the grid and later returns 85 MWh. What is its round-trip efficiency, in %?
- D3
A hypothetical battery costs ₹10,000 per kWh installed and lasts 3,000 cycles at 90 % DoD with 85 % round-trip efficiency. Using the simplified formula, what does each kWh delivered cost, in ₹/kWh?
- D4
A grid battery is rated for 4,000 cycles and is cycled 1 times per day. Roughly how many years will it last (cycle ageing only)?
- D5
A stationary system stores 5,000 kWh at a pack-level 100 Wh/kg. What is the battery mass, in kg?
Check your understanding
Day 2 · about 2.5 h
Comparing storage offers
Comparing two offers
Worked example
Example 7.5: cheaper is not always cheaper
Two illustrative offers:
| Offer | Capital cost (₹/kWh) | Cycle life | Depth of discharge | Round-trip efficiency | Cost per delivered kWh |
|---|---|---|---|---|---|
| A | 20 000 | 6000 | 90 % | 88 % | |
| B | 15 000 | 3000 | 80 % | 92 % |
Offer B is 25 % cheaper to buy and 61 % more expensive per delivered kWh. The comparison depends on how many cycles the application actually needs: if the battery cycles rarely, calendar life, not cycle life, decides.
What the simple figure leaves out
Finance
- Cost of capital and discounting
- Replacement timing
Performance
- Capacity fade over life
- Efficiency of inverters and auxiliaries
Operation
- Maintenance and monitoring
- Calendar life at low cycling
- Warranty terms
Homework
Homework · answers not provided
- Recompute Example 7.5 if the application needs only 200 cycles per year for 15 years. Which offer wins now, and what limits each?
- A 2 MW / 8 MWh system has 87 % round-trip efficiency. How much energy must be bought to deliver 8 MWh? What is the energy lost per cycle?
- Find a public cost figure for utility-scale battery storage (for example from NREL's Annual Technology Baseline) and note its date, geography and uncertainty.
- Explain why energy per kilogram matters little for grid storage.
Further reading
Further reading
- National Renewable Energy Laboratory, Annual Technology Baseline, utility-scale battery storage (latest edition).
- G. L. Plett, Battery Management Systems, Volume I, Artech House, 2015.
Key takeaways
- Grid batteries time-shift energy, keep the grid steady and support peaks.
- A rating such as 100 MW / 400 MWh gives power and energy; their ratio is the duration.
- Round-trip efficiency = energy out ÷ energy in.
- For daily cycling, cost per kWh delivered (cost ÷ cycles × DoD × RTE, simplified) can favour a pricier, longer-lived battery.
- Weight barely matters for stationary storage; cost, life and safety do.
- Cost per delivered kWh = capital cost ÷ (cycles × DoD × efficiency); in Example 7.5 the cheaper battery costs 61 % more per kWh delivered.
- Financing, fade, auxiliaries and calendar life all change the comparison.
- Next in this course: aviation, satellites and aerospace. For the engineering of packs and their costs, see C09.
Sources for this lesson are listed on the References page.